Glass Lined Atmospheric & Pressure Reactors

2.5 Gallon 5 PSI Jacket Glass Jacketed Reactor

Stock #ZG63024

2.5 Gallon 5 PSI Jacket Glass Jacketed Reactor

Stock #ZG63024

Used 10 liter glass jacketed reactor with mixer. Top built by Chemglass. Bottom built by ACE Jacket rated 5 psi. Dual tier teflon agitator with GAST 4AM air drive. Mounted in frame.

Location: Northeast USA

Get a Quote View Details

5 Gallon 8 PSI Jacket Glass Jacketed Reactor

Stock #ZG63025

5 Gallon 8 PSI Jacket Glass Jacketed Reactor

Stock #ZG63025

Used 20 liter glass jacketed reactor with mixer. Unused ACE body Jacket rated 8 psi Used ACE top Gast 4 AM air drive and alloy agitator shaft/blades. Includes frame. Not assembled.

Location: Northeast USA

Get a Quote View Details

5 Gallon 150 Internal, 120 Jacket Pfaudler Glass Lined Reactor Body

Stock #417-15

5 Gallon 150 Internal, 120 Jacket Pfaudler Glass Lined Reactor Body

Stock #417-15

Used Pfaudler approximately 5 gallon glass lined reactor body with top head. Approximately 16″ diameter X 9″ straight side. Internal rated 150 psi @ 450°F. Jacket rated 120 psi @ 350°F. Serial #E184-0472. National board #43062. 1984.

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

10 Gallon 25 Internal, 95 Jacket Pfaudler Glass Lined Reactor

Stock #469V-016-002

10 Gallon 25 Internal, 95 Jacket Pfaudler Glass Lined Reactor

Stock #469V-016-002

Used Pfaudler approximately 10 gallon glass lined reactor. Approximately 14″ diameter X 10″ straight side. Approximately 20″ diameter X 10″ straight side. With hydraulic Pfaudler 2.5W drive and 3-blade glass lined agitator. Rated 25 psi @ 500°F internal, 95 psi...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

16.5 Gallon DeDietrich Pharma Glasslined Reactor Body

Stock #ZG62648

16.5 Gallon DeDietrich Pharma Glasslined Reactor Body

Stock #ZG62648

Used 16.5 gallon DeDietrich pharma glasslined reactor body 16.5 nominal capacity, 18″ ID x 13″ straight side Dished bottom with 2″ center bottom outlet Rated ATM/full vacuum internal @ 400 degrees F, 90 psi coincident with full vacuum @ 400...

Location: Northeast USA

Get a Quote View Details

19 Gallon 150 FV Internal, 150 Jacket R&M Italia Glass Lined Reactor Train

Stock #ZG684-34408

19 Gallon 150 FV Internal, 150 Jacket R&M Italia Glass Lined Reactor Train

Stock #ZG684-34408

Used R&M Italia glass lined reactor train. With approximately 70 liter glass lined reactor with removable dished top and dished bottom heads. Intermediate QVF glass mid section rated 150 psi/full vacuum internal @ 356°F. Jacket rated 150 psi/full vacuum @...

Location: Midwest USA

Get a Quote View Details

20 Gallon 150 FV Internal, 115 Jacket De Dietrich Glass Lined Reactor

Stock #8313-3

20 Gallon 150 FV Internal, 115 Jacket De Dietrich Glass Lined Reactor

Stock #8313-3

Used De Dietrich approximately 20 gallon glass lined reactor. Rated 150 psi/full vacuum internal, 115 psi jacket. 3008 glass. With 1.5 HP motor, vari speed drive. Explosion proof. 3-blade retreat curve agitator. With fin or beaver tail baffles. National board...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

20 Gallon 150 FV Internal, 115 Jacket Pfaudler Glass Lined Reactor

Stock #678-05

20 Gallon 150 FV Internal, 115 Jacket Pfaudler Glass Lined Reactor

Stock #678-05

Used Pfaudler approximately 20 gallon glass lined reactor. Rated 150 psi/full vacuum international at 450°F. Jacket rated 115 psi at 350°F, with clamp top, 9115 glass, no drive, 3-blade retreat curve agitator and H-baffle.

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

20 Gallon 150 FV Internal, 120 Jacket Pfaudler Vertical Glass Lined Reactor

Stock #634-209441

20 Gallon 150 FV Internal, 120 Jacket Pfaudler Vertical Glass Lined Reactor

Stock #634-209441

Used Pfaudler approximately 20 gallon vertical glass lined reactor. 3315 glass. 16″ diameter X 16″ straight side. With clamped dished top and dished bottom. Rated 150 psi/full vacuum internal @ 650°F. Jacket rated 120 psi @ 350°F. SV428200AK air-operated drive,...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

20 Gallon 150 Internal, 90 Jacket Pfaudler P-Series Glass Lined Reactor Body

Stock #9053V-01

20 Gallon 150 Internal, 90 Jacket Pfaudler P-Series Glass Lined Reactor Body

Stock #9053V-01

Reglassed Pfaudler P-series 20 gallon glass lined reactor body. 3315 glass. Rated 150 psi @ 650°F internal. Jacket rated 90 psi @ 350°F. 20″ diameter X 14″ straight side. All mounting brackets. (1) 4.5″ handle hole nozzle, (1) 2.5″ agitator...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

20 Gallon DeDietrich Glass Lined Reactor

Stock #21359-1

20 Gallon DeDietrich Glass Lined Reactor

Stock #21359-1

Used DeDietrich 20 gallon glass lined reactor. Internal rated 150 psi/FV @ 500°F.  Jacket rated 115 psi/100 psi @ 500°F. Lenze drive 1.5 hp with agitator. Clamped top. Glass type 3009. Built 1990. Serial number 34845.

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

20 Gallon DeDietrich Glass Lined Reactor

Stock #21359-2

20 Gallon DeDietrich Glass Lined Reactor

Stock #21359-2

Used DeDietrich 20 gallon glass lined reactor. Internal rated 150 psi/FV @ 500°F.  Jacket rated 115 psi/100 psi @ 500°F. Lenze drive 1.5 hp with agitator. Clamped top. Glass type 3009. Built 1990. Serial number 34847.

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

30 Gal. Pfaudler P-Series Glass Lined Jacketed Reactor

Stock #15999-918

30 Gal. Pfaudler P-Series Glass Lined Jacketed Reactor

Stock #15999-918

Used 30 gallon Pfaudler P-Series glass lined jacketed reactor rated 30 psi internal @ 450°. Jacket rated 115 psi @ 350°, or 100 psi with internal vacuum. Clamp dish top cover: (1) 4″ handhole with hinged sigthglass assembly and (4)...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

30 Gallon 30 FV Internal, 100 Jacket Pfaudler Glass Lined Reactor Body

Stock #725-5909

30 Gallon 30 FV Internal, 100 Jacket Pfaudler Glass Lined Reactor Body

Stock #725-5909

Used Pfaudler approximately 30 gallon glass lined reactor body. Rated 30 psi/full vacuum internal @ 650°F. Jacket rated 100 psi/full vacuum @ 450°F. Full clamp top. (1) 2″ and (2) 1.5″ top openings, 4″ hand hole/sight glass, and 2″ cover...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

30 Gallon 150 FV Internal, 125 Jacket Pfaudler Glass Lined Reactor

Stock #20132-04

30 Gallon 150 FV Internal, 125 Jacket Pfaudler Glass Lined Reactor

Stock #20132-04

Used Pfaudler approximately 30 gallon glass lined reactor. 1’8″ diameter X 1’8″ straight side. With dished top and bottom heads. 9115 glass rated 150 psi/full vacuum internal @ 450°F. Jacket rated 125 psi @ 450°F. Helical stainless steel impeller with...

Location: South USA

Get a Quote View Details

30 Gallon 150 Internal, 100 Jacket De Dietrich Glass Lined Reactor

Stock #663-RE4302

30 Gallon 150 Internal, 100 Jacket De Dietrich Glass Lined Reactor

Stock #663-RE4302

Used De Dietrich approximately 30 gallon glass lined reactor. Rated 150 psi @ 500°F internal. Jacket rated 100 psi @ 500°F. 3009 glass. With Lenzi drive type 12.602. With 3-blade retreat curve agitator and beaver tail baffle.

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

42 Gallon 150 FV Internal, 150 Jacket R&M Italia Glass Lined Reactor Train

Stock #ZG684-34411

42 Gallon 150 FV Internal, 150 Jacket R&M Italia Glass Lined Reactor Train

Stock #ZG684-34411

Used R&M Italia glass lined reactor train. With approximately 160 liter glass lined reactor with removable dished top and dished bottom heads. Intermediate QVF glass mid section rated 150 psi/full vacuum internal @ 356°F/-112°F. Jacket rated 150 psi/full vacuum @...

Location: Midwest USA

Get a Quote View Details

42 Gallon 150 FV Internal, 150 Jacket R&M Italia Glass Lined Reactor Train

Stock #ZG684-34413

42 Gallon 150 FV Internal, 150 Jacket R&M Italia Glass Lined Reactor Train

Stock #ZG684-34413

Used R&M Italia glass lined reactor train. With approximately 160 liter glass lined reactor with removable dished top and dished bottom heads. Intermediate QVF glass mid section rated 150 psi/full vacuum internal @ 356°F. Jacket rated 150 psi/full vacuum @...

Location: Midwest USA

Get a Quote View Details

50 Gallon (200 Liter) Glass Lined Reactor, 60/Full Vacuum Internal

Stock #21196-03

50 Gallon (200 Liter) Glass Lined Reactor, 60/Full Vacuum Internal

Stock #21196-03

Used Approximately 50 Gallon (200 Liter) Glass Lined Reactor Manufacturer: Thale National board: 25 Serial: 6-1-5131/2 Year: 2000 Internal pressure: 60/FV at 350°F Jacket pressure: 150 psi @ 350°F Top, center-mounted 2-blade agitator driven by a 3 hp motor Mounted...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

50 Gallon 150 FV Internal, 110 Jacket Tycon Glass Lined Reactor

Stock #725-5945

50 Gallon 150 FV Internal, 110 Jacket Tycon Glass Lined Reactor

Stock #725-5945

Used Tycon approximately 50 gallon glass lined reactor. Rated 150 psi/full vacuum internal @ 450°F. Jacket rated 110 psi/full vacuum @ 450°F. Type 808 blue glass. Full clamped top. 2 HP, 460 volt, 1725 rpm with 3-blade retreat curve agitator....

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

50 Gallon 300 FV Internal, 105/100 Jacket Pfaudler Reactor

Stock #ZG56172

50 Gallon 300 FV Internal, 105/100 Jacket Pfaudler Reactor

Stock #ZG56172

Used Pfaudler 50 gallon reactor. 300 psi/full vacuum at 450°F internal. 105/100 psi at 350°F jacket. Model #P24-50-300-105. 24″ diameter X 23-1/4″ deep. Jacket is equipped with agitating nozzles. 20″ span special ordered agitator driven by Sperry-Vickers hydraulic system through...

Location: Midwest USA

Get a Quote View Details

72.5 Gallon DeDietrich Pharma Glasslined Reactor Body

Stock #ZG62649

72.5 Gallon DeDietrich Pharma Glasslined Reactor Body

Stock #ZG62649

Used 72.5 gallon DeDietrich pharma reactor body, glasslined. 72.5 gallon nominal capacity 26″ ID x 26″ straight side Dished bottom with 2″ center bottom outlet Rated ATM/full vacuum internal @ -20 deg F to 400 deg F 90 PSI coincident...

Location: Northeast USA

Get a Quote View Details

75 Gallon Glass Lined Reactor

Stock #21196-10

75 Gallon Glass Lined Reactor

Stock #21196-10

Used Approximately 75 Gallon (300 Liter) Glass Lined Reactor Equiped with 3BRC agitator,baffle and drive. Built 1995. Manufacturer: DeDietrich

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

100 Gallon 25 FV Internal, 75 Jacket Pfaudler Glass Lined Reactor

Stock #469V-001-020

100 Gallon 25 FV Internal, 75 Jacket Pfaudler Glass Lined Reactor

Stock #469V-001-020

Used Pfaudler 100 gallon plug-free glass lined reactor. Clamped top 30″ X 30″ T/T. NB # 35108, S/N# E175-0659. Internal 25 psi/full vacuum, jacket 75 psi. Glass #3315/Nucerite. With drive, H-baffle, and 3-blade retreat curve agitator. Excellent fire polish.

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

100 Gallon 25 FV Internal DeDietrich Glass Lined Reactor

Stock #607-81

100 Gallon 25 FV Internal DeDietrich Glass Lined Reactor

Stock #607-81

Used De Dietrich approximately 100 gallon glass lined reactor. 40″ diameter X 3′ straight side. 3008 glass. Clamped top. Rated 25 psi/full vacuum internal @ 400°F. Mounted on removable caster system. With stainless steel clamps and jacket.

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

100 Gallon 150 FV Internal, 100 Jacket Dedietrich Glass Lined Reactor

Stock #787-39

100 Gallon 150 FV Internal, 100 Jacket Dedietrich Glass Lined Reactor

Stock #787-39

Used De Dietrich approximately 100 gallon glass lined reactor. Bolted top. White glass with calibration lines. 2 HP Pfaudler VMX150 drive. 3-blade retreat curve agitator. Fin baffle. Vessel rated 150 psi/full vacuum internal @ 500°F and 100 psi on the...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

100 Gallon 150 FV Internal, 130 Jacket Ceramic Coatings Glass Lined Reactor Body

Stock #593-38

100 Gallon 150 FV Internal, 130 Jacket Ceramic Coatings Glass Lined Reactor Body

Stock #593-38

Used Ceramic Coatings model CT30-100-150 100 gallon glass lined reactor body. Rated 150 psi/full vacuum @ -20/160°F internal. 130 psi @ -20/650°F jacket. HT 2000 glass. (1) 6″ with sight glass. (2) 4″, (2) 3″, bottom (1) 2″.

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

125 Gallon (500 Liter) Glass Lined Reactor

Stock #21196-04

125 Gallon (500 Liter) Glass Lined Reactor

Stock #21196-04

Used Approximately 125 Gallon (500 Liter) Glass Lined Reactor Manufacturer: Thale National board: 22 Serial: 6-1-5130/2 Year: 2000 Internal pressure: 60/FV @ 350°F Jacket pressure: 150 psi @ 350°F Center, top-mounted 2-blade agitator driven by a 5 hp motor Mounted...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

150 Gallon 25 Internal, 100 Jacket Pfaudler Glass Lined Top Reactor

Stock #764-12

150 Gallon 25 Internal, 100 Jacket Pfaudler Glass Lined Top Reactor

Stock #764-12

Used Pfaudler approximately 150 gallon glass lined clamped top reactor. Rated 25 psi internal @ 500°F. Jacket rated 100 psi 500°F. U-stamped. 3-blade retreat curve agitator and H baffle. 2.5 DTW drive with lubricator. Tripod mounted.

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

150 Gallon Pfaudler Glass Lined Reactor

Stock #764-14

150 Gallon Pfaudler Glass Lined Reactor

Stock #764-14

Used Pfaudler approximately 150 gallon glass lined clamped top reactor. 5′ diameter X 6’2″ straight side. 3-blade retreat curve agitator and H baffle. DTW drive with lubricator. 3 HP, 2.2 kW, 3 phase, 60 cycle, 208-230/460 volts.

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

166 Gallon 87 FV Internal, 87 Jacket De Dietrich Glass Lined Reactor

Stock #8447V-01

166 Gallon 87 FV Internal, 87 Jacket De Dietrich Glass Lined Reactor

Stock #8447V-01

Used De Dietrich 166 gallon glass lined reactor. Rated 87 psi/full vacuum internal @ 392°F, with 87 psi jacket rated @ 392°F. 3-blade retreat curve agitator and beaver tail baffle. With Lightnin 7.5 HP drive, model 610-06, 125 rpm output....

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

200 Gallon 25 FV Internal, 100 Jacket Pfaudler Glass Lined Reactor

Stock #402-102061

200 Gallon 25 FV Internal, 100 Jacket Pfaudler Glass Lined Reactor

Stock #402-102061

Used approximately 200 gallon Pfaudler EL Series glass lined reactor. 36″ diameter X 42″ straight side. With clamped dished top and welded dished bottom. Serial #R185-0538, NB #43832, built 1986. Internal rated 25 psi/full vacuum @ 450°F. Jacket rated 100...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

200 Gallon 25 FV Internal Pfaudler Glass Lined Reactor

Stock #402-102060

200 Gallon 25 FV Internal Pfaudler Glass Lined Reactor

Stock #402-102060

Used approximately 200 gallon Pfaudler EL Series glass lined reactor. 36″ diameter X 42″ straight side. With clamped dished top and welded dished bottom. Serial #R185-0539, NB #43805, built 1986. Internal rated 25 psi/full vacuum @ 450°F. Glass #5015. Offset...

Location: Northeast USA

Get a Quote View Details

250 Gallon DeDietrich Glass Lined Reactor

Stock #21196-05

250 Gallon DeDietrich Glass Lined Reactor

Stock #21196-05

Used Approximately 250 Gallon (1,000 Liter) Glass Lined Reactor Manufacturer: De Dietrich Serial: 60410 Year: 1994 Internal pressure: 6 bar (90 psi) @ 200°C (392°F) Jacket pressure: 6 bar (90 psi) @ 200°C (392°F) Center, top-mounted agitator Clamp-top

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

300 Gallon 25 FV Internal, 95 Jacket Pfaudler Glass Lined Reactor

Stock #482-EP700

300 Gallon 25 FV Internal, 95 Jacket Pfaudler Glass Lined Reactor

Stock #482-EP700

Used Pfaudler 300 gallon glass lined reactor. Rated 25 psi/full vacuum internal @ 450°F. Jacket rated 95 psi @ 350°F. #5015 glass. 48″ diameter. Equipped with agitator and baffle. Clamp top. With a 4TW variable speed drive. 12 X 16″...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

300 Gallon 100 Internal, 100 Jacket De Dietrich Glass Lined Reactor

Stock #8170-2

300 Gallon 100 Internal, 100 Jacket De Dietrich Glass Lined Reactor

Stock #8170-2

Used De Dietrich 300 gallon glass lined reactor with drive, agitator and baffle. Rated internal 100 psi @ 400°F. Jacket rated 100 psi @ 400°F. Approximately 48″ diameter X 3′ straight side. With welded dished top and bottom heads. Mounted...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

500 Gallon 25 FV Internal, 95 Jacket Pfaulder Glass Lined Reactor Body

Stock #6947-11

500 Gallon 25 FV Internal, 95 Jacket Pfaulder Glass Lined Reactor Body

Stock #6947-11

Used approximately 500 gallon Pfaulder glass lined reactor body 48″ diameter. Clamped top. Body rated 100/full vacuum @ 450°F. Jacket rated 95 psi @ 350°F. 9115 glass original. Serial #R188-0467, reglass serial number R691-8110, National board #44619. Top head serial...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

500 Gallon 55 FV Internal, 100 Jacket Dedietrich Glass Lined Reactor Body

Stock #482-024

500 Gallon 55 FV Internal, 100 Jacket Dedietrich Glass Lined Reactor Body

Stock #482-024

Used De Dietrich 500 gallon glass lined reactor body. Glass #3008. Rated 55 psi/full vacuum internal @ -20°F/500°F. Jacket rated 100 psi @ -20°F/500°F. Welded dished heads. Several flanged openings on top. No agitator, motor or drive. Serial #32640, built...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

500 Gallon 75 FV Internal, 105 Jacket Dedietrich Glass Lined Reactor

Stock #7608V-3

500 Gallon 75 FV Internal, 105 Jacket Dedietrich Glass Lined Reactor

Stock #7608V-3

Used De Dietrich 500 gallon glass lined reactor. Rated 75 psi full vacuum @ 500°F internal. Jacket 105 psi @ 500°F. National board #5069. Includes baffle and 7.5 HP model 61-0-06 agitator. Retreat blade. Glass #3008. Clamped top. 5′ diameter...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

500 Gallon 100 FV Internal, 100 Jacket Dedietrich Vertical Glass Lined Reactor

Stock #590-89198

500 Gallon 100 FV Internal, 100 Jacket Dedietrich Vertical Glass Lined Reactor

Stock #590-89198

Used De Dietrich approximately 500 gallon vertical glass lined reactor. 4′ diameter X 4’10” straight side. Rated 100 psi/full vacuum @ 400°F internal. Jacket rated 100 psi @ 400°F. 36″ 3-blade retreat curve agitator. 5 HP Philadelphia PTE-06 drive. 2-finger...

Location: South USA

Get a Quote View Details

500 Gallon Glass Lined Reactor Body

Stock #9287-19

500 Gallon Glass Lined Reactor Body

Stock #9287-19

Used approximately 500 gallon glass lined reactor body. 60″ diameter. 25 psi/full vacuum @ 400°F top head. On (3) legs with 3″ clearance. (4) 4″, (1) 8″, and (1) 18″ openings.

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

1,000 Gallon 75 FV Internal, 90 Jacket Pfaudler Glass Lined Reactor Body

Stock #469V-054-004

1,000 Gallon 75 FV Internal, 90 Jacket Pfaudler Glass Lined Reactor Body

Stock #469V-054-004

Used Pfaudler approximately 1,000 gallon glass lined reactor body. Approximately 66″ diameter X 5′ straight side. With flat stainless steel cover. Rated 75 psi/full vacuum internal. Jacket rated 90 psi @ 350°F. 3″ bottom discharge. With top side mounted agitator...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

1,000 Gallon 100 FV Internal, 90 Jacket De Dietrich Glass Lined Reactor

Stock #736-6374

1,000 Gallon 100 FV Internal, 90 Jacket De Dietrich Glass Lined Reactor

Stock #736-6374

Used De Dietrich approximately 1,000 gallon glass lined reactor. Rated 100 psi/full vacuum internal @ 500°F. Jacket rated 90 psi @ 500°F. Type 3008 glass. 5’3″ diameter X 5’11” straight side. With Lightnin 3-blade pitched Glaslock agitator and mechanical seal.

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

1,000 Gallon 100 FV Internal, 90 Jacket Pfaudler Glass Lined Reactor

Stock #ZG711-37374

1,000 Gallon 100 FV Internal, 90 Jacket Pfaudler Glass Lined Reactor

Stock #ZG711-37374

Used Pfaudler approximately 1,000 gallon glass lined reactor. Rated 100 psi/full vacuum internal @ 450°F. Jacket rated 90 psi @ 500°F. 20 HP Pfaudler 5RW agitator drive with mechanical seal. 460 volt XP motor. 3-blade retreat curve Cryolock agitator and...

Location: Midwest USA

Get a Quote View Details

1,000 Gallon 100 FV Internal, 90 Jacket Pfaudler Glass Lined Reactor

Stock #556-82793

1,000 Gallon 100 FV Internal, 90 Jacket Pfaudler Glass Lined Reactor

Stock #556-82793

Used Pfaudler approximately 1,000 gallon glass lined reactor. Rated 100 psi/full vacuum @ 400°F internal. Jacket rated 90 psi @ 400°F. Type 3315 glass. 5’9″ diameter X 4’6″ straight side. With Philadelphia PTE-08 drive. 18″ clearance on legs.

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

2,000 Gallon 100 FV Internal, 90 Jacket Dedietrich Glass Lined Reactor

Stock #7718-3

2,000 Gallon 100 FV Internal, 90 Jacket Dedietrich Glass Lined Reactor

Stock #7718-3

Used De Dietrich 2,000 gallon glass lined reactor. Rated 100 psi/full vacuum @ 500°F internal. Jacket rated 90 psi @ 500°F. National board #2727 Mfg. # 31866. Glass # 3008. Motor is 10 HP vari-speed lug mounted with pipe leg...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

2,000 Gallon 100 Internal, 90 Jacket Pfaudler Glass Lined Reactor

Stock #8228-2

2,000 Gallon 100 Internal, 90 Jacket Pfaudler Glass Lined Reactor

Stock #8228-2

Used Pfaudler 2,000 gallon glass lined reactor. Rated 100 psi/full vacuum @ 350° internal, 90 psi @ 650° jacket. Top head nozzles (1) 10″ (1) 8 1/2″ (2) 6″ (3) 4″. 30″ main cover has (2) 2″ nozzles (1) 4″...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

2,500 Gallon 40 FV Internal, 40 Jacket Dedietrich Glass Lined Reactor

Stock #ZG62409

2,500 Gallon 40 FV Internal, 40 Jacket Dedietrich Glass Lined Reactor

Stock #ZG62409

Used Dedietrich approximately 2,500 gallon glass lined reactor. 84″ diameter x 88″ straight side. Rated 40 psi/full vacuum internal @ 400°F. Conventional jacket rated 90 psi/full vacuum @ 400°F. With welded dished heads. Equipped with GlasLock agitator driven thru Dedietrich...

Location: South USA

Get a Quote View Details

3000 Gallon Pfaudler Reglassed Reactor Body

Stock #21149V-04

3000 Gallon Pfaudler Reglassed Reactor Body

Stock #21149V-04

Reglassed 3,000 gallon reactor body Built by Pfaudler and reglassed by Pfaudler Rated 100/fv @ 650 degrees F internal and 90 psi jacket @ 350 degrees F Reglassed in 2021 In process

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

3000 Gallon Reglassed DeDietrich Reactor Body

Stock #21234-3

3000 Gallon Reglassed DeDietrich Reactor Body

Stock #21234-3

Reglassed DeDietrich 3000 gallon reactor body. Reglassed in 2020 by DeDietrich Internal Pressure: 100/FV @ 500 degrees F. Jacket Pressure: 70 psi @ 500 degrees F. Call for delivery.

Location: South USA

Get a Quote View Details

3000 Gallon Reglassed DeDietrich Reactor Body

Stock #21234-1

3000 Gallon Reglassed DeDietrich Reactor Body

Stock #21234-1

Reglassed DeDietrich 3000 gallon reactor body. Internal Pressure: 100/FV @ 400 degrees F. Jacket Pressure: 90 psi @ 400 degrees F. Reglassed in 2020 by DeDietrich Call for delivery.

Location: South USA

Get a Quote View Details

3000 Gallon Reglassed Pfaudler Reactor Body

Stock #21234-2

3000 Gallon Reglassed Pfaudler Reactor Body

Stock #21234-2

Reglassed Pfaudler 3000 gallon reactor body. Originally built by Pfaudler, reglassed in 2020 by DeDietrich Internal Pressure: 100/FV @ 650 degrees F. Jacket Pressure: 90 psi @ 350 degrees F. Call for delivery.

Location: South USA

Get a Quote View Details

4000 Gallon Glass Lined Reactor, 100 Full Vacuum Internal

Stock #21284-02

4000 Gallon Glass Lined Reactor, 100 Full Vacuum Internal

Stock #21284-02

Used 4,000 Gallon Glass Lined Reactor (To be reglassed) Manufacturer: De Dietrich National board: 2773 Serial: 32146 Year: 1981 Internal pressure: 100/FV @ 410 F Jacket pressure: 90 psi @ 464 F D-style baffle Top, center-mounted Philadelphia drive Cryolock 4-blade...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

4000 Gallon Glass Lined Reactor, 100 Full Vacuum Internal, FDWV Drive

Stock #21284-01

4000 Gallon Glass Lined Reactor, 100 Full Vacuum Internal, FDWV Drive

Stock #21284-01

Used 4,000 Gallon Glass Lined Reactor Manufacturer: Pfaudler National board: 41036 Serial: R181-0031 Year: 1981 Internal pressure: 100/FV @ 450 F Jacket pressure: 90 psi @ 450 F D-style baffle Top, center-mounted Pfaudler drive – Model: FDWV-52700-7B – Serial: 7-00250P...

Location: On Site at Perry (Hainesport, NJ - USA)

Get a Quote View Details

Wunderlich-Malec Mixed Bed Stirred Bioreactor

Stock #ZG683-35162

Wunderlich-Malec Mixed Bed Stirred Bioreactor

Stock #ZG683-35162

Used Wunderlich-Malec mixed bed stirred bioreactor, model AMBIS 1, originally designed for Oglionucleotides, glass reactor and receiver vessels, Delta V batch controls mounted in stainless steel enclosure with controls, 120 volt.

Location: Midwest USA

Get a Quote View Details